Table 22-2 Line Threshold Options For The Ds3I-N-12 Cards; Table 22-3 Electrical Path Options For The Ds3I-N-12 Cards - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

DLP-A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
Table 22-2
Parameter
ES
SES
LOSS
Table 22-3
cards.
Table 22-3
Parameter
Port
CVP
ESP
SESP
SASP
UASP
AISSP
Table 22-4
Cisco ONS 15454 Procedure Guide, R5.0
22-24
Line Threshold Options for the DS3i-N-12 Cards (continued)
Description
Errored seconds
Severely errored seconds
Loss of signal seconds; number
of one-second intervals
containing one or more LOS
defects
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3i-N-12
Electrical Path Options for the DS3i-N-12 Cards
Description
(Display only.) Port number
Coding violations
Errored seconds
Severely errored seconds
Severely errored frame/alarm
indication signal–path
Unavailable seconds–path
Alarm indication signal
seconds–path
describes the values on the Provisioning > SONET Thresholds tabs for the DS3i-N-12 cards.
Options
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the Show Thresholds button.
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the Show Thresholds button.
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the Show Thresholds button.
Options
1 to 12
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click the
Show Thresholds button (DS3 Pbit: Near End only;
DS3 CPbit: Near and Far End).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Chapter 22
DLPs A500 to A599
October 2005

Advertisement

Table of Contents
loading

Table of Contents