Dlp- A340 View Port Status On The Lcd - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 20
DLPs A300 to A399
DLP-A340 View Port Status on the LCD
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Press the Slot button on the LCD panel until the desired slot appears on the LCD.
Step 1
Press the Port button until the desired port appears on the LCD. (Only Port 1 of single-port cards will
Step 2
display actual port status.)
Press the Status button. The LCD will display alarm information for approximately 10 seconds, and then
Step 3
will indicate if the port is in working or protect mode and is active or standby.
Figure 20-4
Figure 20-4
Note
Return to your originating procedure (NTP).
Step 4
March 2005
This task allows you to view OC-N port status without using CTC. The
LCD shows the working/protection provisioning status and the
active/standby line status for ports in 1+1 and BLSR configurations. For
unprotected and path protection ports, the LCD always displays
"Working/Active."
None
NTP-A16 Install the OC-N Cards, page 2-6
As needed
Onsite
None
shows an example of port status on the LCD panel.
Port Status on the LCD Panel
Slot
Status
FAN FAIL
CRIT
MAJ
A blank LCD results when the fuse on the alarm interface panel (AIP) board has blown. If this
occurs, contact Cisco Technical Assistance (TAC). See
Support, and Security Guidelines" section on page lvi
Port
Slot 13
Working / Active
MIN
DLP-A340 View Port Status on the LCD
Port 1
"Obtaining Documentation, Obtaining
for more information.
Cisco ONS 15454 Procedure Guide, R5.0
20-31

Advertisement

Table of Contents
loading

Table of Contents