Table 1-4 Standoffs Required For Eia Types - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 1
Install the Shelf and Backplane Cable
Table 1-4
EIA Type
UBIC-V
UBIC-H
MiniBNC
BNC
High-Density BNC
SMB
AMP Champ
Note
Step 3
Locate the mounting holes where you will install the standoffs on the EIAs you are using.
shows the mounting holes on the UBIC-V.
Figure 1-10
identify the mounting holes on all EIAs by locating the REAR COVER BRACKET LOCATION
designation.
March 2005
Standoffs Required for EIA Types
Required Standoffs for
One Extended Standoff
One 1 3/8-inch
Two 2-inch
One 1 3/8-inch
One 2-inch
One 1 3/8-inch
One 2-inch
One 1 3/8-inch
One 1-inch
As needed, attach additional standoffs to the extended standoffs to meet site-specific cable
management requirements.
shows the mounting holes on the remaining EIA types (MiniBNC, SMB, etc.). You can
Total Required
Standoffs per Shelf
Four 1 3/8-inch
Eight 2-inch
Four 1 3/8-inch
Four 2-inch
Four 1 3/8-inch
Four 2-inch
Four 1 3/8-inch
Four 1-inch
Figure 1-9
shows the mounting holes on the UBIC-H.
Cisco ONS 15454 Procedure Guide, R5.0
NTP-A11 Install the Rear Cover
Figure 1-8
1-23

Advertisement

Table of Contents
loading

Table of Contents