NTP-A95 Upgrade OC-N Spans Manually
Four-port OC-3 to eight-port OC-3
Single-port OC-12 to four-port OC-12
Single-port OC-12 to OC-48
Single-port OC-12 to OC-192
OC-48 to OC-192
You cannot upgrade a four-port OC-12 span. If the ring contains any OC-12-4 cards and you need to
Caution
upgrade all the spans in the ring, you will need to downgrade the OC-12-4 card to a single-port OC-12
card (which is not possible unless only one port on the OC12-4 card is being used).
Complete the
Step 2
Step 3.
According to local site practice, complete the
Step 3
page
Ensure that no alarms or abnormal conditions (regardless of severity), including LOS, LOF, AIS-L, SF,
Step 4
SD, and FORCED-REQ-RING are present. See the
Conditions" task on page 19-63
Note
Complete the appropriate task:
Step 5
DLP-A293 Perform a Manual Span Upgrade on a Two-Fiber BLSR, page 19-57
DLP-A294 Perform a Manual Span Upgrade on a Four-Fiber BLSR, page 19-58
DLP-A295 Perform a Manual Span Upgrade on a Path Protection, page 19-60
DLP-A296 Perform a Manual Span Upgrade on a 1+1 Protection Group, page 19-61
DLP-A297 Perform a Manual Span Upgrade on an Unprotected Span, page 19-62
Note
Note
Cisco ONS 15454 Procedure Guide, R5.0
12-16
"DLP-A60 Log into CTC" task on page
15-4.
During the upgrade/downgrade some minor alarms and conditions display and then clear
automatically. No service-affecting alarms (SA, Major, or Critical) should occur other than
BLSROSYNC, which will clear when the upgrade/downgrade of all nodes is complete. If any
other service-affecting alarms occur, Cisco recommends backing out of the procedure.
A four-node BLSR can take up to five minutes to clear all of the BLSROSYNC alarms. Allow
extra time for a large BLSR to clear all of the BLSROSYNC alarms. Refer to the Cisco ONS
15454 Troubleshooting Guide for information about alarms.
The span upgrade process resets the line's CV-L threshold to factory default. The CV-L threshold
is reset because the threshold is dependent on line rate.
The Span Upgrade option will only be visible and available if the hardware necessary for the
upgrade is present; for example, no upgrade is possible from an OC48 span unless XC10G cards
are installed in the nodes at both ends of the span.
17-66. If you are already logged in, continue with
"NTP-A108 Back Up the Database" procedure on
"DLP-A298 Check the Network for Alarms and
for instructions.
Chapter 12
Upgrade Cards and Spans
January 2005