Highlighted Environmental Alarms - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

DLP-A19 Install Alarm Wires on the Backplane
Figure 17-12
Figure 17-13
Figure 17-13
Cisco ONS 15454 Procedure Guide, R5.0
17-24

Highlighted Environmental Alarms

A
B
A
B
A
B
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
BITS
LAN
IN
FG1
FG2
FG3
FG4
shows alarm pin assignments for the AIC in a shelf for Release 3.3 and earlier.
Cisco ONS 15454 Backplane Pinouts (Release 3.3 or Earlier)
A
B
A
B
A
B
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
BITS
LAN
ENVIR
IN
FG1
FG2
FG3
FG4
Field
Pin
Function
BITS
A1
BITS Output 2 negative (-)
B1
BITS Output 2 positive (+)
A2
BITS Input 2 negative (-)
B2
BITS Input 2 positive (+)
A3
BITS Output 1 negative (-)
B3
BITS Output 1 positive (+)
A4
BITS Input 1 negative (-)
B4
BITS Input 1 positive (+)
LAN
Connecting to a hub, or switch
RJ-45 pin 6 RX-
A1
RJ-45 pin 3 RX+
B1
A2
RJ-45 pin 2 TX-
B2
RJ-45 pin 1 TX+
Connecting to a PC/Workstation or router
A1
RJ-45 pin 2 RX-
RJ-45 pin 1 RX+
B1
A2
RJ-45 pin 6 TX-
RJ-45 pin 3 TX+
B2
A1
Alarm input pair number 1: Reports
ENVIR
closure on connected wires.
B1
ALARMS
IN
A2
Alarm input pair number 2: Reports
closure on connected wires.
B2
A3
Alarm input pair number 3: Reports
closure on connected wires.
B3
A4
Alarm input pair number 4: Reports
closure on connected wires.
B4
A
B
A
B
A
B
7
1
ACO
8
2
5
9
3
6
10
4
ENVIRONMENTAL ALARMS
IN
IN/OUT
IN
FG5
FG6
FG7
A
B
A
B
A
B
A
1
1
1
2
2
2
3
3
3
4
4
4
ALARMS
ACO
X . 25
OUT
FG5
FG6
FG7
Field
Pin
ENVIR
A1
ALARMS
B1
OUT
A2
B2
N/O
A3
B3
A4
B4
ACO
A1
B1
CRAFT
A1
A2
A3
A4
LOCAL
A1
ALARMS
B1
AUD
A2
(Audible)
B2
N/O
A3
B3
A4
B4
A1
LOCAL
ALARMS
B1
VIS
A2
(Visual)
B2
N/O
A3
B3
A4
B4
Chapter 17
A
B
A
A
B
A
1
1
1
2
2
2
3
3
3
4
4
4
MODEM
CRAFT
LOCAL ALARMS
VIS
AUD
FG8
FG9
FG10
B
A
A
B
A
1
1
1
2
2
2
3
3
3
4
4
4
MODEM
CRAFT
LOCAL
ALARMS
VIS
AUD
FG8
FG9
FG10
Function
Normally open output pair number 1
Normally open output pair number 2
Normally open output pair number 3
Normally open output pair number 4
Normally open ACO pair
Receive (PC pin #2)
Transmit (PC pin #3)
Ground (PC pin #5)
DTR (PC pin #4)
Alarm output pair number 1: Remote
audible alarm.
Alarm output pair number 2: Critical
audible alarm.
Alarm output pair number 3: Major
audible alarm.
Alarm output pair number 4: Minor
audible alarm.
Alarm output pair number 1: Remote
visual alarm.
Alarm output pair number 2: Critical
visual alarm.
Alarm output pair number 3: Major
visual alarm.
Alarm output pair number 4: Minor
visual alarm.
DLPs A1 to A99
B
A
B
11
12
IN
FG11
FG12
B
A
B
1
1
2
2
TBOS
3
4
FG11
FG12
March 2005

Advertisement

Table of Contents
loading

Table of Contents