NTP-A290 Replace the Alarm Interface Panel
NTP-A290 Replace the Alarm Interface Panel
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The covers are an integral part of the safety design of the product. Do not operate the unit without the
Warning
covers installed.
Caution
Do not use a 2A AIP with a 5A fan-tray assembly; doing so will cause a blown fuse on the AIP.
If any nodes in an Ethernet circuit are not using Software R4.0 or later, there is a risk of Ethernet traffic
Caution
disruptions. Contact the Cisco Technical Support at 1 800 553-2447 when prompted to do so in the
procedure.
Always use the supplied ESD wristband when working with a powered ONS 15454. Plug the wristband
Caution
cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Caution
Do not perform this procedure on a node with live traffic. Hot-swapping the AIP can affect traffic and
result in a loss of data. For assistance with AIP replacement contact Cisco Technical Support. See the
"Obtaining Documentation, Obtaining Support, and Security Guidelines" section on page
Perform this procedure during a maintenance window. Resetting the active TCC2/TCC2P card can cause
Note
a service disruption of less then 50 ms to OC-N or DS-N traffic. Resetting the active TCC2/TCC2P card
can cause a service disruption of 3 to 5 minutes on all Ethernet traffic due to spanning tree reconvergence
if any nodes in the Ethernet circuit are not using Software R4.0 or later.
Review
Step 1
fan-tray assembly and note the alarms that will occur when an incompatibility occurs.
Ensure that all nodes in the affected network are running the same software version by completing the
Step 2
following substeps before replacing the AIP and repairing circuits:
a.
Cisco ONS 15454 Procedure Guide, R5.0
15-26
Table 15-3 on page 15-23
Log into the node if you have not done so already by completing the
ONS 15454 GUI" procedure on page
This procedure replaces the alarm interface panel (AIP) with a new AIP
on an in-service node without affecting traffic; however, shared packet
rings might need to be deleted and rebuilt after the repair procedure.
Ethernet circuits that traverse nodes with a software release prior to R4.0
will be affected.
#2 Phillips screwdriver
None
As needed
Onsite or remote
Provisioning or higher
to ensure that you have compatible components when replacing the
3-6.
Chapter 15
Maintain the Node
lvi.
"NTP-A23 Log into the
December 2004