NTP-A119 Install the Alarm Expansion Panel
Figure 1-3
Insert and tighten three screws to secure the AEP to the backplane.
Step 4
Connect the AEP cable to the backplane and AEP:
Step 5
Connect the 10 colored wires to the wire-wrap pins on the backplane.
a.
cable wires are connected.
Plug the other end of the AEP cable into AEP connector port. The brown pin is on the top.
b.
Figure 1-4
Cisco ONS 15454 Procedure Guide, R5.0
1-14
Installing Standoffs and the AEP
Wires
AEP cable
Connector
Table 1-1
AEP Wire-Wrap Connections to Backplane Pins
White
Black
A
B
A
B
A
B
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
BITS
LAN
IN
FG1
FG2
FG3
FG4
Violet
Slate
shows AEP and AIC-I signals that each wire carries.
Orange
Yellow
A
B
A
B
A
B
7
1
ACO
8
2
5
9
3
6
10
4
ENVIRONMENTAL ALARMS
IN
IN/OUT
IN
FG5
FG6
FG7
Green
Brown
Blue
Red
Chapter 1
Install the Shelf and Backplane Cable
Figure 1-4
shows where the
A
B
A
A
B
A
1
1
1
2
2
2
3
3
3
4
4
4
MODEM
CRAFT
LOCAL ALARMS
VIS
AUD
FG8
FG9
FG10
B
A
B
11
12
IN
FG11
FG12