NTP-A139 Create a Half Circuit on a BLSR or 1+1 Node
Verify that the test set shows a clean signal. If a clean signal does not appear, repeat Steps
Step 8
to make sure you have configured the test set and cabling correctly.
Inject errors from the test set. Verify that the errors appear at the source and destination nodes.
Step 9
Clear the PM counts for the ports that you tested. See the
Step 10
on page 20-35
Perform protection switch testing appropriate to the SONET topology:
Step 11
Step 12
Perform a bit error rate test (BERT) for 12 hours or follow your site requirements for length of time. For
information about configuring your test set for the BERT, see your test set user guide.
Step 13
After the BERT is complete, print the results or save them to a disk for future reference. For information
about printing or saving test results, see your test set user guide.
Complete the
Step 14
circuit ports from OOS-MA,MT to their previous service states.
Stop. You have completed this procedure.
NTP-A139 Create a Half Circuit on a BLSR or 1+1 Node
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
Complete the
create the half circuit. If you are already logged in, continue with
Step 2
If you want to assign a name to the circuit source and destination ports before you create the circuit,
complete the
Step 3
From the View menu, choose Go to Network View.
Step 4
Click the Circuits tab, then click Create.
Cisco ONS 15454 Procedure Guide, R5.0
6-52
OC-48 cards—You will test either an OC-48c or a multiplexed OC-48. If you are testing an OC-48c
configure the test set for an OC-48c. If you are testing a multiplexed OC-48, configure the test set
for a multiplexed OC-48 and choose the DS-3 and/or DS-1 you will test. For information about
configuring your test set, consult your test set user guide.
OC-192 cards—You will test an OC-192c or a multiplexed OC-192. If you are testing an OC-192c
configure the test set for an OC-192c. If you are testing a multiplexed OC-192, configure the test set
for a multiplexed OC-192 and choose the DS-3 and/or DS-1 you will test. For information about
configuring your test set, consult your test set user guide.
for instructions.
For path protection configurations, see the
page
17-95.
For BLSRs see the
"DLP-A91 BLSR Switch Test" task on page
"DLP-A230 Change a Circuit Service State" task on page 19-19
This procedure creates a DS-1, DS-3, or OC-N circuit from a drop card to
an OC-N trunk card on the same node in a BLSR or 1+1 topology.
None
NTP-A127 Verify Network Turn Up, page 6-4
As needed
Onsite or remote
Provisioning or higher
"DLP-A60 Log into CTC" task on page 17-66
"DLP-A314 Assign a Name to a Port" task on page
Chapter 6
"DLP-A349 Clear Selected PM Counts" task
"DLP-A94 Path Protection Switching Test" task on
17-87.
at the node on the network where you will
Step
2.
20-8. If not, continue with
Create Circuits and VT Tunnels
2
through
7
to change the circuit and
Step
3.