Chapter 19
DLPs A200 to A299
DLP-A225 Enable Alarm Filtering
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
At the node, network, or card view, click the Alarms tab.
Step 1
Step 2
Click the Filter tool at the lower-left side of the bottom toolbar.
Alarm filtering is enabled if the tool is selected and disabled if the tool is raised (not selected).
Alarm filtering will be enabled in the card, node, and network views of the Alarms tab at the node and
for all other nodes in the network. If, for example, the Alarm Filter tool is enabled in the Alarms tab of
the node view at one node, the Alarms tab in the network view and card view of that node will also show
the tool enabled. All other nodes in the network will also have the tool enabled.
If you filter an alarm in card view, the alarm will still be displayed in node view. In this view, the card
will display the color of the highest-level alarm. The alarm is also shown for the node in the network
view.
If you want alarm filtering enabled when you view conditions, repeat Steps
Step 3
window.
If you want alarm filtering enabled when you view alarm history, repeat Steps
Step 4
window.
Return to your originating procedure (NTP).
Step 5
DLP-A227 Disable Alarm Filtering
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
At the node, network, or card view, click the Alarms tab.
Step 1
Click the Filter tool at the lower-right side of the bottom toolbar.
Step 2
Alarm filtering is enabled if the tool is indented and disabled if the tool is raised (not selected).
September 2005
This task enables alarm filtering for alarms, conditions, or event history in
all network nodes.
None
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Retrieve
This task turns off specialized alarm filtering in all network nodes so that
all severities are reported in CTC.
None
DLP-A225 Enable Alarm Filtering, page 19-17
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Retrieve
DLP-A225 Enable Alarm Filtering
1
and
2
using the Conditions
1
and
2
Cisco ONS 15454 Procedure Guide, R5.0
using the History
19-17