Dlp- A378 Provision Line Dcc Terminations - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

DLP-A378 Provision Line DCC Terminations
Note
Return to your originating procedure (NTP).
Step 8
DLP-A378 Provision Line DCC Terminations
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
When LDCC is provisioned, an SDCC termination is allowed on the same port, but is not recommended.
Note
Using SDCC and LDCC on the same port is only needed during a software upgrade if the software
version does not support LDCC. You can provision SDCCs and LDCCs on different ports in the same
node.
In node view, click the Provisioning > Comm Channels > LDCC tabs.
Step 1
Click Create.
Step 2
In the Create LDCC Terminations dialog box, click the ports where you want to create the LDCC
Step 3
termination. To select more than one port, press the Shift key or the Ctrl key.
Note
In the Port Admin State area, click Set to IS to put the port in service.
Step 4
Verify that the Disable OSPF on DCC Link check box is unchecked.
Step 5
If the SDCC termination is to include a non-ONS node, check the Far End is Foreign check box. This
Step 6
automatically sets the far-end node IP address to 0.0.0.0, which means that any address can be specified
by the far end. To change the default to a specific the IP address, see the
Termination" task on page
Step 7
Click OK.
Cisco ONS 15454 Procedure Guide, R5.0
20-62
DCC Termination Failure (EOC) and Loss of Signal (LOS) alarms appear until you create all
network DCC terminations and put the DCC termination OC-N ports in service.
This task creates the LDCC terminations required for administration data,
alarms, signal control information, and messages. LDCCs are three times
larger than SDCCs. In this task, you can also set up the node so that it has
direct IP access to a far-end non-ONS node over the DCC network.
None
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Provisioning or higher
LDCC is used for ONS 15454 DCC terminations. The SONET LDCCs and the SDCC (when not
used as a DCC termination by the ONS 15454) can be provisioned as DCC tunnels. See the
"DLP-A313 Create a DCC Tunnel" task on page
20-60.
Chapter 20
20-7.
"DLP-A375 Change a Line DCC
DLPs A300 to A399