DLP-A168 Change Line and Threshold Settings for the DS3XM-6 Card
Table 18-17
Parameter
Port
CV
ES
SES
SAS
AISS
UAS
Table 18-18
Table 18-18
Parameter
CV
ES
Cisco ONS 15454 Procedure Guide, R5.0
18-44
Electrical Path Threshold Options for the DS3XM-6 Card
Description
(Display only.) Port number
Coding violations
Errored seconds
Severely errored seconds
Severely errored frame/alarm
indication signal
Alarm indication signal
seconds
Unavailable seconds
describes the values on the Provisioning > SONET Thresholds tabs for the DS3XM-6 cards.
SONET Threshold Options for the DS3XM-6 Card
Description
Coding violations
Errored seconds
Chapter 18
Options
1 to 6
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Options
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds (STS and VT Term).
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds (STS and VT Term).
DLPs A100 to A199
March 2007