DLP-A242 Create a BLSR on a Single Node
Ring Type—Enter the ring type (either 2 Fiber or 4 Fiber) of the BLSR.
•
Ring Name—Enter the BLSR ring name. If the node is being added to a BLSR, use the BLSR ring
•
name.
Node ID—Enter the node ID. If the node is being added to a BLSR, use an ID that is not used by
•
other BLSR nodes.
Ring Reversion—Enter the ring reversion time of the existing BLSR.
•
West Line—Enter the slot on the node that will connect to the existing BLSR via the node's west
•
line (port).
East Line—Enter the slot on the node that will connect to the existing BLSR via the node's east line
•
(port).
If you are adding the node to a four-fiber BLSR, complete the following for the second set of fibers:
Span Reversion—Enter the span reversion time of the existing BLSR.
•
West Line—Enter the slot on the node that will connect to the existing BLSR via the node's west
•
line.
East Line—Enter the slot on the node that will connect to the existing BLSR via the node's east line.
•
Click OK.
Step 4
Note
Step 5
Return to your originating procedure (NTP).
Cisco ONS 15454 Procedure Guide, R5.0
19-24
The BLSR is incomplete and alarms are present until the node is connected to other BLSR nodes.