Dlp- A28 Route Coaxial Cables - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 17
DLPs A1 to A99
DLP-A28 Route Coaxial Cables
Purpose
Tools/Equipment
Prerequisite Procedures One or more of the following tasks, as needed:
Required/As Needed
Onsite/Remote
Security Level
Tie wrap or lace the coaxial cables according to local site practice and route the cables through the side
Step 1
cutouts on either side of the ONS 15454. The rubber coated edges of the side cutouts prevent the cables
from chafing.
Step 2
Use short lengths of pigtail RG179 to terminate the shelf assembly.
Use standard RG59 (735A) cable connected to the RG179 for the remainder of the cable run. When using
Step 3
a 10-foot (3.05-m) section of the RG179, you can attach a maximum length of 437 feet (133 m) of RG59
(735A). When using a 30-foot (9.1-m) section of RG179, you can attach a maximum length of 311 feet
(94.8 m) of RG59 (735A).
When using the RG179 cable, the maximum distance available (122 feet, 37.2 m) is less than the
maximum distance available with standard RG59 (735A) cable (306 feet, 93.3 m). The maximum
distance when using the RG59 (734A) cable is 450 feet (137.2 m). The shorter maximum distance
available with the RG179 is due to a higher attenuation rate for the thinner cable. Attenuation rates are
calculated using a DS-3 signal:
Use a figure of 5.0 for total cable loss when making calculations.
proper coaxial cable routing.
March 2005
This task routes the coaxial cables.
RG179, RG59 (735A) #26 AWG cable, or RG59 (734A) #20 AWG cable
As needed
Onsite
None
For RG179, the attenuation rate is 59 dB/kft (decibels per kilo-foot) at 22 MHz.
For RG59 (735A), the attenuation rate is 23 dB/kft at 22 MHz.
DLP-A25 Install Coaxial Cable With BNC Connectors, page 17-32
DLP-A26 Install Coaxial Cable With High-Density BNC Connectors,
page 17-33
DLP-A27 Install Coaxial Cable with SMB Connectors, page 17-33
DLP-A28 Route Coaxial Cables
Figure 17-17
shows an example of
Cisco ONS 15454 Procedure Guide, R5.0
17-35