Cisco ONS 15454 Series Procedure Manual page 785

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 22
DLPs A500 to A599
Note
The Default profile sets severities to standard Telcordia GR-253-CORE settings. If an alarm has an
Inherited profile, it inherits (copies) its severity from the same alarm's severity at the higher level. For
example, if you choose the Inherited profile from the network view, the severities at the lower levels
(node, card and port) will be copied from this selection. A card with an Inherited alarm profile copies
the severities used by the node that contains the card. (If you are creating profiles, you can apply these
separately at any level. To do this, refer to the
task on page
Modify (customize) the new alarm profile:
Step 12
In the new alarm profile column, click the alarm severity you want to change in the custom profile.
a.
Choose a severity from the drop-down list.
b.
c.
Repeat Steps
when you view the alarms or conditions after making modifications:
After you have customized the new alarm profile, right-click the profile column to highlight it.
Step 13
Click Store.
Step 14
If you want to store the profile on a node:
Step 15
In the Store Profile(s) dialog box
a.
Choose the node(s) where you want to save the profile:
b.
If you want to update alarm profile information, click (Synchronize).
c.
If you want to save the profile to a file:
Step 16
In the Store Profile(s) dialog box
a.
Click Browse and navigate to the profile save location.
b.
Enter a name in the File name field.
c.
Click Select to choose this name and location.
d.
Note
October 2005
Up to 10 profiles, including the two reserved profiles, Inherited and Default, can be stored in
CTC.
18-5.)
a
and
b
for each severity you want to customize. Refer to the following guidelines
All CR or MJ default or user-defined severity settings are demoted to MN in NSA situations as
defined in Telcordia GR-474.
Default severities are used for all alarms and conditions until you create and apply a new profile.
Changing a severity to inherited (I) or unset (U) does not change the severity of the alarm.
If you want to save the profile to only one node, click the node in the Node Names list.
If you want to save the profile to all nodes, click Select All.
If you do not want to save the profile to any nodes, click Select None.
Long file names are supported. CTC supplies a suffix of *.pfl to stored files.
DLP-A518 Create a New or Cloned Alarm Severity Profile
"DLP-A117 Apply Alarm Profiles to Cards and Nodes"
(Figure
22-4), click To Node(s).
(Figure
22-4), click To File.
Cisco ONS 15454 Procedure Guide, R5.0
22-11

Advertisement

Table of Contents
loading

Table of Contents