Dlp- A523 Discontinue Alarm Suppression - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 22
DLPs A500 to A599
b.
c.
Alarms that apply directly to this port will change appearance as described in
raised on the entire card will remain raised.) A raised AS-CMD alarm that shows the port as its object
will appear in either alarm window. For example, if you suppressed alarms for Port 1 on the Slot 16
OC-48 card, the alarm object will show "FAC-16-1."
Return to your originating procedure (NTP).
Step 4
DLP-A523 Discontinue Alarm Suppression
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
If multiple CTC sessions are open, discontinuing suppression in one session will discontinue
suppression in all other open sessions.
To discontinue alarm suppression for the entire node:
Step 1
a.
b.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the System object will be cleared
in all views.
To discontinue alarm suppression for individual cards:
Step 2
a.
b.
c.
d.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the slot object (for example,
SLOT-16) will be cleared in all views.
To discontinue alarm suppression for ports:
Step 3
a.
October 2005
Check the Suppress Alarms column check box for the row of the port where you want to suppress
alarms
(Figure 22-5 on page
Click Apply.
This task discontinues alarm suppression and reenables alarm reporting on
a port, card, or node.
None
DLP-A522 Suppress Alarm Reporting, page 22-17
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Provisioning or higher
In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tab.
Uncheck the Suppress Alarms check box.
In the node view, click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
Locate the card that was suppressed in the slot list.
Uncheck the Suppress Alarms column check box for that slot.
Click Apply.
Click the following tabs:
22-13).
Cisco ONS 15454 Procedure Guide, R5.0
DLP-A523 Discontinue Alarm Suppression
Step
1. (However, alarms
22-19

Advertisement

Table of Contents
loading

Table of Contents