Figure 16-24 Alarm Filter Dialog Box Conditions Tab - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

In the Show Severity area, click the check boxes for the severities [Critical (CR), Major (MJ), Minor
Step 3
(MN), or Not-Alarmed (NA)] you want to be reported at the network level. Leave severity check boxes
deselected (unchecked) to prevent those severities from appearing.
When alarm filtering is disabled, all alarms show.
Step 4
In the Time area, click the Show alarms between time limits check box to enable it. Click the up and
down arrows in the From Date, To Date, and Time fields to modify what period of alarms are shown.
To modify filter parameters for conditions, continue with
continue with
Click the filter dialog box Conditions tab
Step 5
Figure 16-24
When filtering is enabled, conditions in the Show list are visible and conditions in the Hide list are
invisible.
To move conditions individually from the Show list to the Hide list, click the > button.
To move conditions individually from the Hide list to the Show list, click the < button.
To move conditions collectively from the Show list to the Hide list, click the >> button.
To move conditions collectively from the Hide list to the Show list, click the << button.
Note
Click Apply and OK.
Step 6
Alarm and condition filtering parameters are enforced when alarm filtering is enabled (see the
"DLP-H84 Enable Alarm Filtering" task on page
alarm filtering is disabled (see the
Return to your originating procedure (NTP).
Step 7
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
16-104
Step
6.
Alarm Filter Dialog Box Conditions Tab
Conditions include alarms.
Step
(Figure
16-24).
16-102), and the parameters are not enforced when
"DLP-H88 Disable Alarm Filtering" task on page
Chapter 16
5. If you do not need to modify them,
16-107).
DLPs H1 to H99
78-19416-01