Dlp-H54 Optical 1+1 Protection Test - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Step 9
Click Finish.
Note
Note
Return to your originating procedure (NTP).
Step 10

DLP-H54 Optical 1+1 Protection Test

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
From the View menu choose Go to Network View.
Step 1
Click the Alarms tab and click Synchronize.
Step 2
a.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
16-72
ESH—Sets the End System Hello (ESH) propagation frequency. End system NEs transmit
ESHs to inform other ESs and ISs about the NSAPs it serves. The default is 10 seconds. The
range is 10 to 1000 seconds.
ISH—Sets the Intermediate System Hello PDU propagation frequency. Intermediate system
NEs send ISHs to other ESs and ISs to inform them about the unlocked NETs it serves. The
default is 10 seconds. The range is 10 to 1000 seconds.
IIH—Sets the Intermediate System to Intermediate System Hello PDU propagation frequency.
The IS-IS Hello PDUs establish and maintain adjacencies between ISs. The default is 3 seconds.
The range is 1 to 600 seconds.
IS-IS Cost—Sets the cost for sending packets on the LAN subnet. The IS-IS protocol uses the
cost to calculate the shortest routing path. The default metric cost for LAN subnets is 20. It
normally should not be changed.
EOC (DCC Termination Failure) and LOS (Loss of Signal) alarms are present until you create
all network DCC terminations and put the DCC termination optical ports in service.
There are four possibilities for the appearance of DCCs: green/solid, green/dashed, gray/solid,
gray/dashed. DCC appearance corresponds to the following states: active/routable,
active/nonroutable, failed/routable, or failed/nonroutable. Circuit provisioning uses
active/routable links. Selecting a node or span in the graphic area displays information about the
node and span in the status area.
This task verifies that a 1+1 protection group will switch traffic properly.
The test set specified by the acceptance test procedure.
DLP-H29 Log into CTC, page
a test circuit created as part of the topology acceptance test.
Required
Onsite
Provisioning or higher
Verify that the alarm filter is not on. See the
page 16-107
as necessary.
16-43;
"DLP-H88 Disable Alarm Filtering" task on
Chapter 16
DLPs H1 to H99
78-19416-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents