Chapter 17
DLPs H100 to H199
To set the filter for ring, node, link, and source and drop type, click the Advanced tab and complete the
Step 4
following. If you do not want to make advanced filter selections, continue with
If you made selections on the General tab, click Yes in the confirmation box to apply the settings.
a.
In the Advanced tab of the Circuit Filter dialog box, set the following filter attributes as necessary:
b.
Click OK. Circuits matching the attributes in the Filter Circuits dialog box appear in the Circuits
Step 5
window.
To turn filtering off, click the Filter icon in the lower right corner of the Circuits window. Click the icon
Step 6
again to turn filtering on, and click the Filter button to change the filter attributes.
Return to your originating procedure (NTP).
Step 7
78-19416-01
State—Choose one: OOS (display only out-of-service circuits), unlocked (display only
in-service circuits; OCHNCs have unlocked status only), or OOS-PARTIAL (display only
circuits with cross-connects in mixed service states).
Protection—Choose a protection type to filter the circuits. For more information about
protection types, see
Table 17-4 on page
Slot—Enter a slot number to filter circuits based on the source or destination slot; otherwise
leave the field blank.
Port—Enter a port number to filter circuits based on the source or destination port; otherwise
leave the field blank.
Type—Choose one: Any (type not used to filter circuits), VC high-order path (displays only
VC high-order path circuits), VC low-order path (displays only VC low-order path circuits),
VC low-order path Tunnel (displays only VC low-order path tunnels), VC_HO_Path_Circuit
(displays VC high-order path VCAT circuits), VC_LO_Path_Circuit (displays VT VCAT
circuits), or VC low-order path Aggregation Point (displays only VC low-order path
aggregation points).
Size—Click the appropriate check boxes to filter circuits based on size: VC low-order path
circuits are 1.5. ONS 15310-MA SDH VC high-order path circuits are 1, 3c, 6c, 9c, 12c, 24c,
and 48c. VCAT circuits are VC-12-nv or VC3-nv, where n is the number of members.
The check boxes shown depend on the Type field selection. If you chose Any, all sizes are
available. If you chose VC low-order path, VC-12 or VC12 are available. If you chose
VC_HO_Path_Circuit, only VC-12 is available. If you chose VC high-order path, only VC
high-order path sizes are available, and if you chose VC low-order path Tunnel or VC low-order
path Aggregation Point, only VC3 is available.
Ring—Choose the ring from the drop-down list.
Node—Click the check boxes by each node in the network to filter circuits based on node.
Link—Choose the desired link in the network.
Source/Drop—Choose one of the following to filter circuits based on whether they have one or
multiple sources and drops: One Source and One Drop Only or Multiple Sources or Multiple
Drops.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-10.
Step
5.
17-13