Return to your originating procedure (NTP).
Step 7

DLP-H115 Delete Circuits

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
database and circuits.
Verify that traffic is no longer carried on the circuit and that the circuit can be safely deleted.
Step 2
Click the Alarms tab and click Synchronize.
Step 3
a.
b.
Step 4
From the View menu, choose Go to Network View.
Click the Circuits tab.
Step 5
Choose the circuits you want to delete, then click Delete.
Step 6
In the Delete Circuits confirmation dialog box, check one or both of the following, as needed:
Step 7
Note
Step 8
Complete one of the following:
78-19416-01
This task deletes circuits.
None
DLP-H29 Log into CTC, page 16-43
Circuits must exist on the network. See
Low-order Path Tunnels"
As needed
Onsite or remote
Provisioning or higher
"NTP-H102 Back Up the Database" procedure on page 14-2
Verify that the alarm filter is not on. See the
page 16-107
as necessary.
Verify that no unexplained alarms appear on the network. If alarms are present, investigate and
resolve them before continuing. Refer to the Cisco ONS 15310-MA SDH Troubleshooting Guide if
necessary.
Set drop ports to OOS—Puts the circuit source and destination ports to locked-enabled,disabled if
the circuit is the same size as the port or is the only circuit using the port. If the circuit is not the
same size as the port or the only circuit using the port, CTC will not change the port service state.
Notify when completed—If checked, the CTC Alerts confirmation dialog box indicates when all
circuit source/destination ports are in locked-enabled,disabled and the circuit is deleted. During this
time, you cannot perform other CTC functions. If you are deleting many circuits, waiting for
confirmation can take a few minutes. Circuits are deleted whether or not this check box is checked.
The CTC Alerts dialog box will not automatically open to show a deletion error unless you
checked All alerts or Error alerts only in the CTC Alerts checkbox. For more information, see
the
"DLP-H36 Configure the CTC Alerts Dialog for Automatic Popup" task on page
the CTC Alerts dialog is not set to open automatically with a notification, the red triangle inside
the CTC Alerts toolbar icon indicates that a notification exists.
for circuit creation procedures.
"DLP-H88 Disable Alarm Filtering" task on
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2