Dlp-H112 Edit A Circuit Name - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Note
Click Apply.
Step 6
Step 7
If a confirmation dialog box appears, click Yes to continue. If the Circuit State Transitions dialog box
appears, view the results and click OK.
CTC will not change the service state of the circuit source and destination port in certain circumstances.
For example, if a port is in loopback (locked-enabled,loopback & maintenance), CTC will not change
the port to unlocked-enabled. In another example, if the circuit size is smaller than the port, CTC will
not change the port service state from unlocked-enabled to locked-enabled,disabled. If CTC cannot
change the port service state, you must change the port service state manually. For more information,
see the
Step 8
Return to your originating procedure (NTP).

DLP-H112 Edit a Circuit Name

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node or network view, click the Circuits tab.
Step 1
Click the circuit you want to rename, then click Edit.
Step 2
If you want to edit a VCAT circuit member name, complete the following steps in the Edit Circuit
Step 3
window. If not, continue with the
a.
b.
In the General tab, click the Name field and edit or rename the circuit. Names can be up to 48
Step 4
alphanumeric and/or special characters.
Note
Click Apply.
Step 5
From the File menu, choose Close.
Step 6
If you changed the name of a VCAT circuit member, repeat
Step 7
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-16
CTC will not allow you to change a drop port service state from unlocked-enabled to
locked-enabled,disabled. You must first change a port to the locked-enabled,maintenance
service state before putting it in the locked-enabled,disabled service state.
"DLP-H50 Change the Service State for a Port" task on page
This task edits a circuit name, including VCAT circuit member names.
None
DLP-H29 Log into CTC, page 16-43
As needed
Onsite or remote
Provisioning or higher
Click the Members tab.
Click the VCAT member that you want to edit, then click Edit Member. The Edit Member window
opens.
If you will create a monitor circuit on this circuit, do not make the name longer than
44 characters because monitor circuits add "_MON" (four characters) to the circuit name.
Step
4.
Chapter 17
16-67.
Step 6
for the Edit Circuit window.