Before You Begin
Click Finish. One of the following actions occurs based on the circuit properties you selected:
Step 18
In the Circuits window, verify that the circuits you just created appear in the circuits list.
Step 19
Complete the
Step 20
test circuit.
Stop. You have completed this procedure.

NTP-H41 Create a Manually Routed DS-3 or E3 Circuit

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
create the circuit. If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
From the View menu, choose Go to Network View.
Step 3
Click the Circuits tab, then click Create.
Step 4
In the Circuit Creation dialog box, complete the following fields:
Step 5
Click Next.
Step 6
Define the circuit attributes:
Step 7
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
5-18
If you entered 1 in the Number of Circuits field, CTC creates the circuit.
If you entered more than 1 in the Number of Circuits field and chose Auto-ranged, CTC
automatically creates the number of circuits entered in the Number of Circuits field. If autoranging
cannot complete all the circuits, for example, because sequential ports are unavailable at the source
or destination, a dialog box appears. Set the new source or destination for the remaining circuits,
then click Finish to continue autoranging. After completing the circuits, the Circuits window
appears.
If you entered more than 1 in the Number of Circuits field and did not choose Auto-ranged, the
Circuit Creation dialog box appears for you to create the remaining circuits. Repeat Steps
through
17
for each additional circuit. After completing the circuits, the Circuits window appears.
"NTP-H46 Test Electrical Circuits" procedure on page
This procedure creates a DS-3 or E3 circuit and allows you to choose the
circuit route.
None
NTP-H36 Verify Network Turn-Up, page 5-4
As needed
Onsite or remote
Provisioning or higher
"DLP-H29 Log into CTC" task on page 16-43
"DLP-H56 Assign a Name to a Port" task on page
Circuit Type—Choose VC high-order path (both DS-3 and E3) or VC low-order path (E3 only).
Number of Circuits—Enter the number of DS-3 or E3 circuits that you want to create. The default
is 1.
Auto-ranged—Applies to automatically routed circuits only. If you entered more than 1 in Number
of Circuits, uncheck this check box. (The check box is unavailable if only one circuit is entered in
Number of Circuits.)
Chapter 5
Create Circuits and VC Low-order Path Tunnels
5-24. Skip this step if you built a
at a node on the network where you will
Step
2.
16-75. If not, continue with
5
Step
3.
78-19416-01