Figure 17-4
Click Finish. On the Circuits tab, the circuit status for the Roll From port changes from DISCOVERED
Step 10
to ROLL_PENDING.
Click the Rolls tab
Step 11
the following conditions are met, continue with
If the Roll Valid Signal status is true, a valid signal was found on the new port.
If the Roll Valid Signal status is false, a valid signal was not found. Wait until the signal is found
before continuing with the next step. To cancel the roll, see the
page
The roll is a one-way destination roll and the Roll Valid Signal is false. It is not possible to get a
"true" Roll Valid Signal status for a one-way destination roll.
Note
You can force a signal onto the Roll To circuit by using the Force Valid Signal button. If you choose
Force Valid Signal, traffic on the circuit that is involved in the roll might drop depending on
conditions at the other end of the circuit when the roll is completed. You must force a signal if the
circuits do not have a signal or have a bad signal and you want to complete the roll.
Note
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-74
Selecting a New Endpoint
(Figure
17-5). For the pending roll, view the Roll Valid Signal status. When one of
17-84.
You cannot cancel an automatic roll after a valid signal is found.
For a one-way destination roll in manual mode, you do not need to force the valid signal.
Step
12.
"DLP-H189 Cancel a Roll" task on
Chapter 17
DLPs H100 to H199
78-19416-01