Security Level
Multirate PPMs for the ONS 15310-MA SDH support STM1, STM4, and STM16 line rates.
Note
In node view, double-click the 15310E-CTX-K9 card (ONS 15310-MA SDH).
Step 1
Click the Provisioning > Pluggable Port Modules tabs.
Step 2
In the Pluggable Port Modules area, click Create. The Create PPM dialog box appears.
Step 3
In the Create PPM dialog box, complete the following:
Step 4
Step 5
Click OK. The newly created port appears in the Pluggable Port Modules area. The row on the Pluggable
Port Modules area turns white and the Actual Equipment Type column lists the equipment name.
Verify that the PPM appears in the list in the Pluggable Port Modules area. If it does not, repeat Steps
Step 6
through 5.
Repeat the task to provision a second PPM.
Step 7
Click OK.
Step 8
Continue with the
Step 9
multirate PPM for STM1 or STM4.
Return to your originating procedure (NTP).
Step 10

DLP-H193 Provision the Optical Line Rate

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-88
This task provisions a multirate (STM1/STM4/STM16) PPM in CTC. If a
multirate PPM was preprovisioned, skip this procedure and go directly to
the
None
DLP-H29 Log into CTC, page 16-43
Required
Onsite or remote
Provisioning or higher
PPM—Click the slot number where the SFP is installed from the drop-down list.
PPM Type—Click the number of ports supported by your SFP from the drop-down list. If only one
port is supported, PPM (1 port) is the only option.
"DLP-H193 Provision the Optical Line Rate" task on page 17-88
This task provisions the line rate on the ONS 15310-MA SDH (STM1,
STM4, or STM16) on a multirate PPM. Single-rate PPMs do not need to
be provisioned.
None
DLP-H29 Log into CTC, page 16-43
DLP-H192 Provision a Multirate Pluggable Port Module, page 17-88
Required
"DLP-H193 Provision the Optical Line Rate" task on page
Chapter 17
DLPs H100 to H199
17-88.
3
to provision the
78-19416-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents