Before You Begin
Broadband Electrical ports (BBE) DS3/E3—On the ONS 15310-MA SDH, if you are testing a clear
channel DS3/E3, use the BNC connectors on the BICs on the rear of the chassis. Set the test set for
clear channel DS3/E3. For information about configuring your test set, consult your test set user
guide.
STM-M—If you are testing an STM-M circuit, set the test set for the applicable circuit size. For
information about configuring your test set, consult your test set user guide.
Verify the integrity of all patch cables that will be used in this test by connecting one end to the test set
Step 8
transmit (Tx) connector and the other end to the test set receive (Rx) connector. If the test set does not
run error-free, check the cable for damage and check the test set to make sure it is set up correctly before
continuing.
Step 9
Create a physical loopback at the circuit destination:
Attach one end of a patch cable to the destination port Tx connector.
a.
Attach the other end to the port Rx connector.
b.
At the circuit source:
Step 10
Connect the Tx connector of the test set to the circuit Rx connector.
a.
Connect the test set Rx connector to the circuit Tx connector.
b.
Verify that the test set displays a clean signal. If a clean signal is not displayed, repeat Steps
Step 11
8
to make sure the test set and cabling are configured correctly.
Inject BIT errors from the test set. To verify that you have a complete end-to-end circuit, verify that the
Step 12
errors display at the test set.
From the View menu choose Go to Network View.
Step 13
Click one of the two spans leaving the circuit source node and complete the
Step 14
Switching Test" task on page
In network view, click the other circuit source span and complete the
Step 15
Switching Test" task on page
Set up and complete a BER Test. Use the existing configuration and follow your site requirements for
Step 16
the length of time. Record the test results and configuration.
Step 17
Complete the
Remove any loopbacks, switches, or test sets from the nodes after all testing is complete. Refer to the
Step 18
Cisco ONS 15310-MA SDH Troubleshooting Guide if necessary.
Step 19
Click the Alarms tab and click Synchronize.
a.
Verify that the alarm filter is not on. See the
page 16-107
b.
Verify that no unexplained alarms appear on the network. If alarms are present, investigate and
resolve them before continuing. Refer to the Cisco ONS 15310-MA SDH Troubleshooting Guide if
necessary.
Complete the
c.
your hard drive.
On the Conditions tab, and click Retrieve.
Step 20
Verify that the network does not have any unexplained conditions. If unexplained conditions are
a.
present, resolve them before continuing. Refer to the Cisco ONS 15310-MA SDH Troubleshooting
Guide if necessary.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
4-12
16-74.
16-74.
"DLP-H115 Delete Circuits" task on page 17-19
as necessary.
"DLP-H223 Export CTC Data" task on page 18-20
"DLP-H55 Path Protection
to delete the test circuit.
"DLP-H88 Disable Alarm Filtering" task on
to export alarm data to a file on
Chapter 4
Turn Up a Network
1
through
"DLP-H55 Path Protection
78-19416-01