Retrieve And Display Conditions; Conditions Column Descriptions; Figure 10-4 Viewing Fault Conditions Under The Conditions Tab; Table 10-4 Conditions Columns Description - Cisco ONS 15327 User Documentation

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 10
Alarm Monitoring and Management
or Minor) or a condition (Not Reported or Non Alarmed.) See the trouble notifications information in
Chapter 14, "Alarm Troubleshooting,"
conditions.
Displaying all existing fault conditions is helpful while troubleshooting the ONS 15327. The Conditions
tab does not adhere to Telcordia guidelines for reporting alarms, events, and conditions. Alarm reporting
under the Alarms tab is Telcordia-compliant.

10.2.3.1 Retrieve and Display Conditions

At the node view, click the Conditions tab and the Retrieve Conditions button to retrieve the current
set of all existing fault conditions from the ONS 15327 as maintained by the alarm manager. Users can
perform the same operation at the card view for the card level and at the network view for the network
level. See

Figure 10-4 Viewing fault conditions under the Conditions Tab

10.2.3.2 Conditions Column Descriptions

Table 10-4

Table 10-4 Conditions Columns Description

Column
Node
Object
Type
Slot
June 2002
Figure
10-4.
lists the Conditions tab column headings and the information recorded in each column.
Information Recorded
Node where the condition occurred (displayed in network view only)
TL1 AID for the alarmed object
Card type in this slot
Slot where the condition occurred (displayed in network and node view only)
for more information on the classifications for alarms and
Cisco ONS 15327 User Documentation, R3.3
Viewing ONS 15327 Alarms
10-5