Dlp-H46 Set Up Internal Timing - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Chapter 16
DLPs H1 to H99
If the state is set to OOS, continue with
Step 7
information:
Return to your originating procedure (NTP).
Step 8

DLP-H46 Set Up Internal Timing

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
Internal timing is Stratum 3 and not intended for permanent use. All ONS 15310-MA SDH nodes should
be timed to a Stratum 2 or better primary reference source.
Step 1
In node view, click the Provisioning > Timing > General tabs.
Step 2
In the General Timing area, enter the following:
78-19416-01
BITS In Facility Type—Provisions the BITS In facility type (E1).
BITS In State—If Timing Mode is set to External or Mixed, set the BITS In State for BITS-1 to
unlocked (in service) if the BITS input port is connected to the external timing source. If Timing
Mode is set to Line, set the BITS In State to OOS (out of service).
BITS Out Facility Type—Provisions the BITS Out facility type (E1).
BITS Out State—If equipment is connected to the node's BITS output pins and you want to time the
equipment from a node reference, set the BITS Out State for BITS-1 to unlocked, if the BITS Out
connection is used for the external equipment. If equipment is not attached to the BITS output
connector, set the BITS Out State to OOS.
Coding—Choose the coding used by your BITS reference, either B8ZS (binary 8-zero substitution)
or AMI (alternate mark inversion).
Framing—Choose the framing used by your BITS reference, either ESF (Extended Super Frame) or
SF (D4) (Super Frame).
Sync Messaging—Check this check box to enable SSM. SSM is not available if Framing is set to
Super Frame.
AIS Threshold—If SSM is disabled or Super Frame is used, choose the quality level where a node
sends an alarm indication signal (AIS) from the BITS 1 Out pins. An AIS alarm is raised when the
optical source for the BITS reference falls to or below the SSM quality level defined in this field.
LBO—If you are timing an external device connected to the BITS Out pins, choose the distance
between the device and the ONS 15310-MA SDH. Options are: 0-133 ft. (default), 124-266 ft.,
267-399 ft., 400-533 ft., and 534-655 ft. Line build out (LBO) relates to the BITS cable length.
This task sets up internal Stratum 3 timing for an ONS 15310-MA SDH.
None
DLP-H29 Log into CTC, page 16-43
As needed (use only if a BITS source is not available)
Onsite or remote
Provisioning or higher
Timing Mode—Set to External.
SSM Message Set—Set to Generation 1.
Step
8. If the state is set to unlocked, complete the following
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
16-63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents