Dlp-H77 View Conditions - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

DLP-H77 View Conditions

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
In the card, node, or network view, click the Conditions tab.
Step 2
Click Retrieve.
The Retrieve button requests the current set of fault conditions from the node, card, or network. The
window is not updated when conditions change on the node. You must click Retrieve to see any changes.
The conditions include all fault conditions raised on the node, whether or not they are reported.
Note
Events that are reported as Major (MJ), Minor (MN), or Critical (CR) severities are alarms. Events that
are reported as Not-Alarmed (NA) are conditions. Conditions that are not reported at all are marked
Not-Reported (NR) in the Conditions window severity column.
Conditions that have a default severity of Critical (CR), Major (MJ), Minor (MN), or Not-Alarmed (NA)
but are not reported due to exclusion or suppression are shown as NR in the Conditions window.
Note
Current conditions are shown with the severity chosen in the alarm profile, if used. (For more
information about alarm profiles, see the
Profiles" procedure on page
Note
Note
If you want to apply exclusion rules, check the Exclude Same Root Cause check box at the node or
Step 3
network view, but do not check the Exclude Same Root Cause check box in card view.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
16-94
This task is used to view conditions [events with a Not-Reported (NR)
severity] at the card, node, or network level. Conditions give you a clear
record of changes or events that do not result in alarms.
None
DLP-H29 Log into CTC, page 16-43
As needed
Onsite or remote
Retrieve or higher
Alarms can be unreported when they are filtered out of the display. See the
Alarm Filtering" task on page 16-102
For more information about alarm suppression, see the
task on page
16-105.
8-6.)
When a port is placed in the Out-of-Service and Management, Maintenance
(locked-enabled,maintenance) service state, it raises an Alarms Suppressed for Maintenance
(AS-MT) condition. For information about alarm and condition troubleshooting, refer to the
Cisco ONS 15310-MA SDH Troubleshooting Guide.
When a port is placed in the Out-of-Service and Autonomous, Automatic In-Service
(unlocked-disabled,automaticInService) service state but is not connected to a valid signal, it
generates a loss of signal (LOS) alarm.
for information.
"DLP-H86 Suppress Alarm Reporting"
"NTP-H60 Create, Download, and Assign Alarm Severity
Chapter 16
DLPs H1 to H99
"DLP-H84 Enable
78-19416-01

Hide quick links: