Chapter 18
DLPs H200 to H299
Table 18-7
Parameter
SF BER
SD BER
Line Type
Line Coding
Line Length
automaticInServi
ce Soak
Table 18-8
Table 18-8
Parameter
Port
CV
ES
SES
LOSS
Table 18-9
78-19416-01
Line Options for DS-3 Ports (continued)
Description
Sets the signal fail bit error
rate.
Sets the signal degrade bit
error rate.
Defines the line framing type.
Defines the DS-3
transmission coding type.
Defines the distance (in feet)
from backplane connection to
the next termination point.
Automatic in-service soak.
describes the values on the Provisioning > Line Thresholds tab for the DS-3 ports.
Line Thresholds Options for DS-3 Ports
Description
Port number (display only).
1 to 3
Coding violations. Available for Near End and Far End.
Errored seconds. Available for Near End and Far End.
Severely errored seconds. Available for Near End and Far End.
Number of one-second intervals containing one or more loss of signal (LOS) defects.
Available for Near End and Far End.
describes the values on the Provisioning > Elect Path Thresholds tab for the DS-3 ports.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
Options
1E-3
1E-4 (default)
1E-5
1E-5
1E-6
1E-7 (default)
1E-8
1E-9
UNFRAMED
M13 (multiplexed E1 to DS-3 framing)
C Bit (parity framing)
B3ZS (Bipolar 3 Zero Substitution)
0 - 225 (default)
226 - 450
Duration of valid input signal in hh.mm after
which the port is set in service by the software.
0 to 48 hours, 15-minute increments.
18-41