DLP-H139 Change the Node Timing Source

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The following task can be service affecting; perform it during a scheduled maintenance window.
Caution
Step 1
In node view, click the Provisioning > Timing tabs.
Step 2
In the General Timing area, change any of the following information:
See the
In the Reference Lists area, you can change the following information:
Step 3
Note
Step 4
In the BITS Facilities area, you can change the following information:
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-42
This task changes the SDH timing source for the ONS 15310-MA SDH.
None
DLP-H29 Log into CTC, page 16-43
As needed
Onsite or remote
Provisioning or higher
Timing Mode
Because mixed timing can cause timing loops, Cisco does not recommend using the Mixed
Note
Timing option. Use this mode with care.
SSM Message Set
Quality of RES
Revertive
Reversion Time
"DLP-H45 Set Up External or Line Timing" task on page 16-61
Reference lists define up to three timing references for the node and up to six BITS Out
references. BITS Out references define the timing references used by equipment that can be
attached to the node's Mechanical Interface Cards (MICs). If you attach equipment to the BITS
Out pins, you normally attach it to a node with Line mode because equipment near the external
timing reference can be directly wired to the reference.
NE Reference
BITS 1 Out
Chapter 17
DLPs H100 to H199
for field descriptions.