1.9 Circuits and Timing

If the condition does not clear, replace the Slot 8 cross-connect card with an identical, spare card.
Step 4
If the condition does not clear, replace the spare card placed in Slot 8 with the original cross-connect
Step 5
card.
Right-click the Slot 10 cross-connect card.
Step 6
Choose Reset Card and click OK. The Slot 8 cross-connect card becomes active and Slot 10 becomes
Step 7
standby.
Step 8
If you have switched the Slot 8 card to active and continue to see CTNEQPT-PBWORK reported against
all I/O cards in the node, this indicates the Slot 8 card has a bad oscillator. If this is indicated, complete
the following substeps. If not, go to
a.
b.
c.
Step 9
If you then see the CTNEQPT-PBPROT condition raised against all I/O cards, verify that
CTNEQPT-PBWORK has cleared on the I/O cards. This indicates that Slot 10 has a bad oscillator. If so,
complete the following substeps:
a.
b.
c.
1.9 Circuits and Timing
This section provides solutions to circuit creation and reporting errors, as well as common timing
reference errors and alarms.
1.9.1 OC-N Circuit Transitions to Partial State
Symptom
the following partial state conditions:
Table 1-27
Cisco ONS 15454 Troubleshooting Guide, R4.6
1-88
Replace the Slot 8 cross-connect card with a spare card. (The Slot 10 card is made active.)
Reseat the Slot 10 cross-connect card to make Slot 8 active.
Verify that the CTNEQPT-PBWORK condition has cleared on all I/O cards.
Replace the Slot 10 cross-connect card with a spare card. (Slot 10 remains standby.)
Reseat the Slot 8 cross-connect card to activate the Slot 10 card and make Slot 8 standby.
Verify that the CTNEQPT-PBPROT condition has cleared on all I/O cards.
An automatic or manual transition of a circuit from one state to another state results in one of
OOS_PARTIAL: At least one of the OC-N connections in the circuit is in OOS state and at least
one other connection in the circuit is in IS, OOS_MT, or OOS_AINS state.
OOS_MT_PARTIAL: At least one connection in the OC-N circuit is in OOS_MT state and at least
one other connection in the circuit is in IS, OOS_MT, or OOS_AINS state.
OOS_AINS_PARTIAL: At least one connection in the OC-N circuit is in the OOS_AINS state and
at least one other connection in the circuit is in IS or OOS_AINS state.
describes the possible problems and the solutions.