3
Robot position when removing axis-3 from parallel arm - screws in area 2
1
2
Removing the axis-3 gearbox from parallel arm, step 2 - screws in area 2
Use this procedure to remove the screws that secure the axis-3 gearbox to the
parallel arm, in area 2.
1
Product manual - IRB 8700
3HAC052853-001 Revision: F
Action
Remove the screws in area 1.
Action
Turn on the power and jog the robot to the
specified position:
Axis 1: no significance as long as
the robot is fitted to the foundation.
Axis 2: -65°
Axis 3: 0°
Axis 4: 0°
Axis 5: 0°
Axis 6: No significance.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Action
DANGER
Never remove the screws on both axis-2
and axis-3 at the same time! One side must
always be attached when the gearbox on
the other side is removed. If not, there is a
potential risk that a severe will accident
happen.
© Copyright 2015-2018 ABB. All rights reserved.
4.8.4 Replacing the axis-3 gearbox
Note
xx1500003114
Lower arm is hidden in this figure, to get a
better view.
Note
Note
Continues on next page
4 Repair
Continued
723