4 Repair
4.7.4 Replacing the axis-5 motor
Continued
2
3
4
5
Continues on next page
612
Action
Refit the cable gland cover.
Note
Replace the gasket if damaged.
Connect the connectors.
Connect in accordance with the markings
on the connectors.
Inspect the o-ring.
Note
Replace if damaged.
CAUTION
When refitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
© Copyright 2015-2018 ABB. All rights reserved.
Note
Attachment screws: M5x16 (2 pcs)
xx1200001016
xx1200001015
O-ring: 3HAC054692-002
xx1200001070
Product manual - IRB 8700
3HAC052853-001 Revision: F