4 Repair
4.6.4 Unloading and restoring the balancing device
Continued
Equipment, etc.
Screw M16x80
Standard toolkit
Required consumables
Consumable
Molykote 1000
Unloading the pressure of the balancing device
Use these procedures to unload the pressure of the balancing device.
Preparations before unloading the pressure of balancing device
1
2
Unloading the pressure of the balancing device
1
Continues on next page
548
Action
Jog the robot to calibration position.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.