ABB IRB 8700 Series Product Manual page 105

Hide thumbs Also See for IRB 8700 Series:
Table of Contents

Advertisement

Inspecting the oil level in axis-1 gearbox
1
2
3
4
5
6
7
8
Product manual - IRB 8700
3HAC052853-001 Revision: F
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
WARNING
Handling gearbox oil involves several safety risks.
Before proceeding, please read the safety inform-
ation in the section
Safety risks during work with
gearbox lubricants (oil or grease) on page
CAUTION
The gearbox can contain an excessive pressure
that can be hazardous. Use caution when the oil
plug is opened, in order to let out the excess
pressure.
Open the ventilation plug.
Note
The ventilation plug shall be opened prior to the
inspection plug, in order to release possible
pressure inside.
Open the inspection plug.
Inspect the oil level.
Required oil level is a few millimeters below the
lower edge of the inspection hole.
Add or drain oil, if required.
© Copyright 2015-2018 ABB. All rights reserved.
3.3.1 Inspecting the oil level in axis-1 gearbox
Note
37.
xx1500001993
xx1500001992
Type of oil and total amount is de-
tailed in Technical reference
manual - Lubrication in gearboxes.
Further information about how to
drain or fill with oil is found in sec-
tion
Changing oil, axis-1 gearbox
on page
Continues on next page
3 Maintenance
Continued
141.
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 8700-550/4.20Irb 8700-800/3.50Irc5