ABB IRB 8700 Series Product Manual page 240

Hide thumbs Also See for IRB 8700 Series:
Table of Contents

Advertisement

4 Repair
4.4.3 Replacing the SMB
Continued
8
9
Refitting the SMB battery
1
2
3
4
Concluding procedure
1
Continues on next page
240
Action
Secure the SMB cover.
If cabling is used for 7th axis (option), refit the
connector R2.FB7 to the SMB cover and tighten
with 6 Nm.
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
The unit is sensitive to ESD on page 32
Get a hold of the battery cable in the recess for
the battery and reconnect.
Place the battery in the recess.
Refit the battery cover.
Action
Update the revolution counter.
© Copyright 2015-2018 ABB. All rights reserved.
Note
Attachment screws: M6x16 8.8 (5 pcs)
Tightening torque: 6 Nm
xx1300000669
Note
xx1300000829
Attachment screws: M6x16 8.8 (2 pcs)
Tightening torque: 6 Nm
Note
See
Updating revolution counters on
page
801.
Product manual - IRB 8700
3HAC052853-001 Revision: F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 8700-550/4.20Irb 8700-800/3.50Irc5

Table of Contents