ABB IRB 8700 Series Product Manual page 204

Hide thumbs Also See for IRB 8700 Series:
Table of Contents

Advertisement

4 Repair
4.4.1 Removing the cable harness
Continued
5
6
Disconnecting the axis-1, axis-2, axis-3 and axis-4 motor cables
1
2
Continues on next page
204
Action
Remove the cable gland cover.
Tip
Make a note in which direction the cable
exit hole is facing, if the motor shall be re-
moved too. The motor shall be refitted in
the same position.
Use caution and pull out the motor cables.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
Unscrew the attachment screws with
washers and remove the motor cover.
© Copyright 2015-2018 ABB. All rights reserved.
Note
xx1500002717
Note
xx1200001135
Product manual - IRB 8700
3HAC052853-001 Revision: F