1.3.5.3 Login Through Telnet (Inband Management)

This topic describes how to log in to the MA5600T/MA5603T/MA5608T using the upstream
port (inband management port) in the telnet mode to maintain and manage the MA5600T/
MA5603T/MA5608T. You are advised to use SSH mode.
Prerequisites
Engineers are logged in to the MA5600T/MA5603T/MA5608T by using the local serial port or
the ETH port.
NOTE
l
l
Networking
Figure 1-18
Figure 1-19
Issue 01 (2014-04-30)
You can run the idle-timeout command to set the terminal timeout time. if you do not input
commands within the specified timeout time, the system disconnects the terminal. By
default, the terminal timeout time is set to 5 minutes. If you do not run any commands
within 5 minutes, the system disconnects with the terminal. To perform any operation, you
must have to log in to the system again.
In the commissioning procedure, you must use the command, It is recommended that you
know well the command modes
Figure 1-17
Login
enable
User mode
huawei>
quit
disable
The default IP address of the maintenance Ethernet port (ETH port on the control board) is 10.11.104.2,
and the subnet mask is 255.255.255.0.
For details about how to log in to the MA5600T/MA5603T/MA5608T by using the local
serial port, see
1.3.5.1 Login Through the Local Serial
For details about how to log in to the MA5600T/MA5603T/MA5608T by using the ETH
port, see the following:
– Configure the IP address of the PC that is used for logging in to the MA5600T/
MA5603T/MA5608T. This IP address is on the same subnet as the IP address of the
maintenance Ethernet port but is not the IP address of the maintenance Ethernet port.
For example, configure the IP address to 10.11.104.6.
– After logging in to the MA5600T/MA5603T/MA5608T, run the ip address command
to change the IP address of the device to 10.50.1.10/24.
– Change the IP address of the PC to be on the same subnet as the IP address of the
maintenance Ethernet port but is not the IP address of the maintenance Ethernet port.
For example, change the IP address of the device to 10.50.1.11/24.
shows an example network for inband management through telnet in a LAN, and
shows an example network for inband management through telnet in a WAN.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
first.Figure 1-17
shows how to switch command modes.
config
Global config mode
Privilege mode
huawei#
huawei(config)#
quit
1 Commissioning
Interface/config mode
interface
huawei(config-if-...)
quit
return