1.5 Maintenance and Management Commissioning

To ensure the stability of the MA5600T/MA5603T/MA5608T, you need to verify the
maintainability and reliability of the device after completing the stand-alone commissioning and
interconnection commissioning.

1.5.1 Configuring the System Energy-Saving Function

This topic describes how to power off a board that is not configured with any services for a long
time to reduce the system power and therefore to reduce the system energy consumption.
Prerequisites
NOTE
The board must support the power-off mode and the energy-saving mode.
Context
Energy-saving modes include the manual energy-saving mode and automatic energy-saving
mode.
l
l
l
Issue 01 (2014-04-30)
Only the MA5600T supports this operation.
Manual energy-saving mode (powering off a board manually). You can manually power
off an unused board in the subrack according to the plan for the energy-saving purpose.
When the service is provisioned from the OSS server to a board that is powered off, the
system prompts that the board is currently powered off. In this case, you can manually
power on the board according to the prompt.
Automatic energy-saving mode (automatically powering off a board). When the automatic
energy-saving mode is enabled, the system supports a series of energy-saving measures
according to the referenced energy-saving profile. These measures include the following:
battery energy saving, shutting down unused boards, putting unused xDSL ports to sleep
mode and shutting down the laser on unused xPON ports. An energy-saving profile is a set
of energy-saving measures. The system provides three typical energy-saving profiles. You
can query the profiles but cannot modify, rename, or delete them. The three typical profiles
are as follows:
– Standard energy-saving profile standard, with ID 1. It is the default energy-saving
profile in the system. In this profile, all the energy-saving measures are disabled.
– Basic energy-saving profile basic, with ID 2. In this profile, some energy-saving
measures that do not affect the current services are enabled, such as:
– Shutting down unused boards
– Shutting down the laser on unused xPON ports and putting unused xDSL ports to
sleep mode
– Deep energy-saving profile deep, with ID 3. In this profile, all the energy-saving
measures are enabled, and the battery energy saving may affect the service running.
To power on a board that is powered off manually, you must run the board power-on
command to manually power it on.