huawei(config)#multi-service-port vlan aoe board 4 vpi 0 vci 35 inbound
traffic-table index 22 outbound traffic-table index 22
Step 8 Bind the PVCs to PW 20 in batches to create an ATM PWE3 service.
Since the VPI/VCI parameters of cells on PVCs at different ports are the same, the VPI/VCI
parameters must be changed once before the cells on client-side PVCs are encapsulated into
PWs. This ensures that the VPI/VCI parameters are unique for cells on each PVC in the PW.
l Bind PVCs and PWs in batches for UBR services.
huawei(config)#multi-pw-ac-binding pvc board 2 vpi 0 vci 35 from-outvpi 0 outvci
32
from-invpi 1 invci 32 pw 20 static transmit-label 8450 receive-label 8460
l Bind PVCs and PWs in batches for VBR services.
huawei(config)#multi-pw-ac-binding pvc board 3 vpi 0 vci 35 from-outvpi 0 outvci
33
from-invpi 1 invci 33 pw 21 static transmit-label 8451 receive-label 8461
l Bind PVCs and PWs in batches for CBR services.
huawei(config)#multi-pw-ac-binding pvc board 4 vpi 0 vci 35 from-outvpi 0 outvci
34
from-invpi 1 invci 34 pw 22 static transmit-label 8452 receive-label 8462
Step 9 Query the PW status.
huawei(config)#display pw-ac-binding pvc 0/2/0 vpi 0 vci 35
Total : 1
----------------------------------------------------------------------------
F/S/P
VPIVCI
----------------------------------------------------------------------------
0/2/0 0 35
----------------------------------------------------------------------------
Note
----End
Result
The ATM packets can be transparently transmitted in the MPLS network and the ATM-based
services can be provided normally.
Configuration File
vlan 300 standard
port vlan 300 0/19 1
interface loopback 0
ip address 5.5.5.5 32
quit
mpls lsr-id 5.5.5.5
mpls
mpls te
mpls rsvp-te
quit
mpls l2vpn
mpls vlan 300
interface vlanif 300
ip address 192.168.2.20 24
mpls
mpls te
mpls rsvp-te
quit
ospf 1
opaque-capability enable
area 200
Issue 01 (2014-04-30)
(Up/Down :
1/0
PW
ID
20
: F--Frame, S--Slot, P--Port
*: Secondary
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Configuration Example of the Private Line Service
Static/LDP :
PW
PROTO
RECEIVE TRNS
STATE TYPE
LABEL
LABEL
up
static 8460
8450
1/0)
PW
INDEX
20
413