SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
For profiles that can be applied to an SIP interface, if parameters in those profiles are changed,
those profiles must be reapplied to the SIP interface so that the changed parameters can take
effect. For profiles that can be bound to an SIP interface, if parameters in those profiles are
changed, those profiles do not need to be rebound to the SIP interface and the changed parameters
can take effect.
The method for applying an SIP agent profile is introduced in step
introduce the methods for applying an interface common profile, an SIP service data profile,
and a POTS port profile, and the method for binding a digitmap to an SIP interface.
1.
2.
3.
4.
Step 9 (Optional) Configure the SIP user codec.
Run the sippstnuser codec command to configure the SIP user codec. The SIP user codec will
not be configured independently in this example.
Step 10 Save the data.
huawei(config)#save
----End
Issue 01 (2014-04-30)
Apply an interface common profile.
Run the if-sip attribute command to apply an interface common profile to an SIP interface
or configure the interface customized parameters, or run the ont-if-sip bat-apply from
command to bulk apply the interface common profiles to SIP interfaces. If you use these
two commands to apply the interface common profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default interface common profile, namely interface common profile 1
is used.
Apply an SIP service data profile.
Run the sippstnuser rightflag command to apply an SIP service data profile to an SIP
interface or configure the interface customized parameters, or run the ont-sippstnuser bat-
apply from command to bulk apply the SIP service data profiles to SIP interfaces. If you
use these two commands to apply the SIP service data profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default SIP service data profile, namely SIP service data profile 1 is
used.
Apply a POTS port profile.
Run the pstnport electric command to apply a POTS port profile to an SIP interface or
configure the interface customized parameters, or run the ont-pstnport electric bat-
apply command to bulk apply the POTS port profiles to SIP interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
Bind a digitmap profile.
Run the sippstnuser digitmap command to bind a digitmap profile to an SIP interface, or
run the ont-sippstnuser bat-bind from command to bulk apply the digitmap profiles to
SIP interfaces. If you use these two commands to bind the SIP service data profiles to SIP
ports repeatedly, the last configurations take effect.
In this example, the default digitmap profile, namely digitmap profile 1 is used.