SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Item
SHDSL port
Internal SPC
Procedure
Step 1 Configure the working mode and clock source of the EDTB board.
Configure the working mode of the board to voice, working sub-mode to service, and clock
source to E1 line clock.
NOTE
To configure the private line service leasing timeslots, the working mode of the board must be configured to
voice and the sub-mode must be configured to service.
huawei(config)#interface edt 0/3
huawei(config-edt-0/3)#board workmode voice
huawei(config-edt-0/3)#runmode service
huawei(config-edt-0/3)#set clockmode line 0
Step 2 Configure the attributes of the SHDSL port.
1.
Issue 01 (2014-04-30)
Set the signaling mode of the SHDSL port to unframe.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Configuration Example of the Private Line Service
Data
Port IDs: 0/3/16 and 0/3/17
Port signaling mode: unframe
Line profile ID of the port: 2
l Rate: 512 kbit/s
l Channel mode: TDM
l Data frame type: V35
l Clock mode: system clock
l Other parameters: default values
l Bound to port 0/3/16
Line profile ID of the port: 3.
l Rate: 256 kbit/s
l Channel mode: TDM
l Data frame type: V35
l Clock mode: system clock
l Other parameters: default values
l Bound to port 0/3/17
Establish internal SPCs between B channels 0-7 of SHDSL port
0/3/16 and timeslots 1-8 of E1 port 0/3/0.
Establish internal SPCs between B channels 0-3 of SHDSL port
0/3/17 and timeslots 9-12 of E1 port 0/3/0.
NOTE
In CCS mode, timeslot 0 of the E1 port is used to send the frame locating
information but is not used to send data. Therefore, it cannot be used
for internal semi-permanent connection (SPC).