SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Example
To query the log records of all users within the period from 10:00:00 on 2009-08-24 to 18:00:00
on 2009-08-24, do as follows:
huawei>display log
{ all<K>|cli<K>|failure<K>|index<K>|memory<K>|name<K>|snmp<K> }:all
{ <cr>|start-date<D><yyyy-mm-dd> }:2009-08-24
{ -<K>|<cr>|start-time<T><hh:mm:ss> }:10:00:00
{ -<K>|<cr> }:-
{ end-date<D><yyyy-mm-dd> }:2009-08-24
{ <cr>|end-time<T><hh:mm:ss> }:18:00:00
Command:
---------------------------------------------------------------------------
No.
Time: 2009-08-24 17:14:48
Cmd:
---------------------------------------------------------------------------
No.
Time: 2009-08-24 17:08:08
Cmd:
Index1: hwFrameIndex: 0
Index2: hwSlotIndex: 9
hwBackupServerIpAddr: 10.78.217.35
hwBackupMode: 3
hwBackupFileName: /bmsuser/7341374.poz
hwBackupContent: 68
hwBackupUserNam
---------------------------------------------------------------------------
No.
---- More ( Press 'Q' to break ) ----

1.5.4 Checking the System Switchover

After the active/standby switchover is performed, the services of the active control board are
switched to the standby control board. This ensures that the services run in the normal state.
Prerequisites
l
l
Precautions
l
l
Issue 01 (2014-04-30)
display log all 2009-08-24 10:00:00 - 2009-08-24 18:00:00
UserName
65
test03
switch language-mode
UserName
64
private
...
UserName
63
private
An active control board and a standby control board must be configured on the device, and
the cables must be connected correctly on the boards.
The patch status of the active and standby control boards must be consistent with the
hardware environment.
If the data of the active and standby control boards is not completely synchronized, the
system prohibits the active/standby switchover.
NOTE
Run the display data sync state command to query the data synchronization status of the active and
standby control boards.
When the communication between the active and standby control boards fails or the standby
control board is faulty, the system prohibits the active/standby switchover.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Domain
IP-Address
--
10.71.42.55
Domain
IP-Address
--
10.78.217.35
Domain
IP-Address
--
10.78.217.35
1 Commissioning
191

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents