Commissioning The Interconnection With The Sip Interface - Huawei SmartAX MA5603T Configuration Manual

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
huawei(config)#save
----End
Result
After the MG is interconnected with the MGC successfully, you can run the display if-mgcp
all command to confirm that the MG interface is in the normal state.
huawei(config)#display if-mgcp all
--------------------------------------------------------------------------
MGID
--------------------------------------------------------------------------
0
--------------------------------------------------------------------------
Configuration File
vlan 50 smart
port vlan 50 0/19 0
interface vlanif 50
ip address 10.50.1.10 24
quit
voip
ip address media 10.50.1.10 10.50.1.1
ip address signaling 10.50.1.10
quit
ip route-static 10.10.1.0 255.255.255.0 10.50.1.1
interface mgcp 0
y
if-mgcp attribute mgip 10.50.1.10 mgport 2727 domainName MA5600T/MA5603T/
MA5608T.com mgcip_1 10.14.1.4 mgcport_1 2727
reset
y
quit
save

1.4.5 Commissioning the Interconnection with the SIP Interface

This topic describes how to check whether the SIP interface can normally communicate with
the IP multimedia subsystem (IMS) through the SIP protocol.
Service Requirements
In the network as shown in
l
l
l
l
Issue 01 (2014-04-30)
State
Normal
Figure
The MA5600T/MA5603T/MA5608T uses the SIP protocol.
The media IP address is the same as the signaling IP address, and the media stream and the
signaling stream are transmitted upstream through the same Ethernet port on the GIU board.
The media stream and the signaling stream use the default QoS policy for upstream
transmission.
The IMS identifies the SIP interface through the signaling IP address (IP address of the SIP
interface), and their communication packets do not contain any VLAN tag.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
MGPort MGIP
2727
10.50.1.10
1-77, the service requirements are as follows:
1 Commissioning
MGCPort MGCIP/DomainName
2727
10.14.1.4
171