Huawei SmartAX MA5603T Configuration Manual page 53

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Figure 1-14 Network example for outband management through telnet in a WAN
PC
Data Plan
Table 1-12
a LAN and in a WAN respectively.
Table 1-12 Data plan for the outband management through telnet in a LAN
Item
Maintenance Ethernet port of the MA5600T/
MA5603T/MA5608T
Maintenance terminal
Table 1-13 Data plan for the outband management through telnet in a WAN
Item
Maintenance Ethernet port of the MA5600T/
MA5603T/MA5608T
Maintenance terminal
Router port connecting to the MA5600T/
MA5603T/MA5608T
Issue 01 (2014-04-30)
PC
LAN
and
Table 1-13
provide the data plan for the outband management through telnet in
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
PC
Data
IP address: 10.50.1.10/24
NOTE
By default, the IP address of the maintenance
Ethernet port (ETH port on the control board) is
10.11.104.2, and the subnet mask is
255.255.255.0.
IP address: 10.50.1.20/24 (in the same subnet
as the IP address of the maintenance Ethernet
port)
Data
IP address: 10.50.1.10/24
NOTE
By default, the IP address of the maintenance
Ethernet port (ETH port on the control board) is
10.11.104.2, and the subnet mask is
255.255.255.0.
IP address: 10.10.1.10/24
IP address: 10.50.1.1/24
1 Commissioning
Router
Access node