SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Monitoring
Parameter
Displayed on
the Host
Digital 4
Digital 5
Digital 6
Door alarm
Wiring alarm
Battery Tem
environment
Tem/environment
Hum
NOTE
Configuration Process
The monitoring parameters can be reported to the control system only when the data for the
EPS75-4815AF is configured correctly in the system.
Table 1-29
Issue 01 (2014-04-30)
Device Port
JTD5
JTD6
JTD7
JTM1
JTP1
BAT_WE
TEM-HU
Before adding a user-defined analog or monitoring digital parameter, make sure that the port corresponding
to this parameter is properly connected to an environment monitoring cable.
lists the commands used during the configuration.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Application in the N66
Cabinet
Not connected by default,
used to add a user-defined
monitoring digital
parameter
Not connected by default,
used to add a user-defined
monitoring digital
parameter
Not connected by default,
used to add a user-defined
monitoring digital
parameter
Not connected by default,
used to monitor a door
status sensor
Not connected by default,
used to monitor a MDF
sensor
Battery temperature sensor Battery temperature
Not connected by default.
1 Commissioning
Application in the
F01D500 Cabinet
Smoke sensor
Heat exchanger
Door status sensor of
the MDF compartment
Door status sensors of
the device compartment
and heat exchanger
compartment
MDF
sensor
Temperature and
humidity sensor