Troubleshooting methods for the Internet access service
1.
Check whether configurations are complete on the OLT.
– Run the display ont info command to query the ONU status to check whether the
ONU is registered successfully.
– Run the display service-port command to check whether the Internet access
service flow is configured and whether the inner VLAN ID of the service flow is
consistent with that in the data plan.
– If a native VLAN is configured for the VDSL2 port on the ONU, run the display
ont port attribute command in the xPON board mode to check whether the native
VLAN is correct.
2.
Check the upstream and downstream ports by checking the MAC address learning
status.
a.
Run the display mac-address vlan command to check the MAC address learning
status of the Internet service VLAN.
– If the upstream port does not learn a MAC address, check the network
connections between the upstream port and upper-layer devices and check
the configurations of upper-layer devices.
– If the downstream port does not learn a MAC address, check whether the
ONU is activated, whether the PC is connected to the right port on the ONU,
and whether the PC is working properly.
b.
Run the display ont-learned-mac command to check whether the ONU
connecting to the PON port learned any MAC addresses.
If not, check whether the ONU properly connects to the PC or home gateway
(HGW).
Verify the voice service using call emulation.
1.
Run the ont emulational call command to configure a call emulation test.
huawei(config)#test
huawei(config-test)#ont emulational call caller-port 0/1/0 1 1 telno
28777192
{ <cr>|caller-stop-time<K> }:
Command:
ont emulational call caller-port 0/1/0 1 1 telno 28777192
2.
The ONU outputs the call emulation result after the test is complete.
huawei(config-test)#
----------------------------------------------------------------
F/S/P
ONT-ID
ONT-POTS ID
Test type
Detected number
Reported number
Current status
Test Result
----------------------------------------------------------------
Troubleshooting methods for the voice service.
1.
Check whether configurations are complete on the OLT.
– Run the display ont info command to query the ONU status to check whether the
ONU is registered successfully.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
: 0/1/0
: 0
: 1
: caller emulational call test
: 28777192
: 28777192
: test end
: success