SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Table 1-5 Usage of the DIP switches
Electric
Switch
S5-1
S5-2
S5-3
S5-4
S6-1
S6-2
S6-3
S6-4
S6-5
S6-6
S6-7
S6-8
Table 1-6
Table 1-6 Mapping between S5-1 to S5-4 and sensor ports
Electric Switch
S5-1
S5-2
S5-3
S5-4
S6-1 to S6-5 are used to set the sub-node IDs of the H801ESC board.
between S6-1 to S6-5 and sub-node IDs.
Issue 01 (2014-04-30)
Used to set the external sensor type of JTA1-JTA4. For detailed information,
see
Table
1-6.
l ON: The external sensors are of the current type.
l OFF: The external sensors are of the voltage type.
Used to set the sub-node ID. This value must correspond with the configured
ESC sub-node ID in the system and cannot be identical to the address value of
the sub-node. Such restrictions ensure that the H801ESC board can
communicate with the control board. For detailed information, see
l ON: The mapping address bit is 0.
l OFF: The mapping address bit is 1.
Reserved.
Used to set the baud rate of the communication between the H801ESCA board
and the control board.
l ON: The baud rate is 19200 bit/s (default).
l OFF: The baud rate is 9600 bit/s.
describes the mapping between S5-1 to S5-4 and sensor ports.
OFF
The external sensor of JTA1 is of the
voltage type.
The external sensor of JTA2 is of the
voltage type.
The external sensor of JTA3 is of the
voltage type.
The external sensor of JTA4 is of the
voltage type.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Usage
ON
The external sensor of JTA1
is of the current type.
The external sensor of JTA2
is of the current type.
The external sensor of JTA3
is of the current type.
The external sensor of JTA4
is of the current type.
Table 1-7
1 Commissioning
Table
1-7.
lists the mapping
8