Huawei SmartAX MA5603T Configuration Manual page 864

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
VLAN Planning and VLAN Translation Policy on Ethernet Cascading Networks
Application
Scenario
FTTB and FTTC
Ethernet cascading
(MDUs serving as
independent nodes)
Issue 01 (2014-04-30)
VLAN
VLAN Translation
Plan
MDU/GE Remote Extended Subrack
Two-tag
Without HGWs: The outer S-VLAN is
VLAN
planned based on MDUs and the inner C-
solution
VLAN identifies a user. Ensure that the C-
VLANs of users using the same S-VLAN do
not repeat each other.
LAN access using HGWs:
l Untagged upstream packets of HGWs:
l Tagged upstream packets of HGWs:
xDSL access using HGWs:
l Asynchronous transfer mode (ATM)
l Packet transfer mode (PTM) upstream
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11 FTTB and FTTC Solution Configuration
MDUs map C-VLANs based on user ports
and add S-VLANs to packets.
MDUs translate user VLANs to C-VLANs
(user VLAN <-> C-VLAN) and add S-
VLANs to packets.
upstream transmission: MDUs translate
PVCs to C-VLANs (PVC <-> C-VLAN)
and add S-VLANs to packets. Ensure that
the C-VLANs of users using the same S-
VLAN do not repeat each other.
transmission: Untagged upstream packets
of HGWs: MDUs map C-VLANs based
on user ports and add S-VLANs to
packets. Tagged upstream packets of
HGWs: MDUs translate user VLANs to
C-VLANs (user VLAN <-> C-VLAN)
and add S-VLANs to packets. Ensure that
the C-VLANs of users using the same S-
VLAN do not repeat each other.
OLT/
Master
Subrac
k
The
OLT
transmit
s
packets
transpar
ently.
839

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t

Table of Contents