SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Precautions
1.
2.
This operation interrupts the ongoing services carried on the currently used MG interface. Hence,
exercise caution when performing this operation.
Data Plan
For configuration rules and description of configuration items, see
Service Data
Item
SIP
interface
data
NOTE
(It must be
the same as
that on the
IMS core
network
device.)
Issue 01 (2014-04-30)
An ONU supports both the H.248 and SIP protocols; however, these two protocols are
mutually exclusive. You can run the display protocol support command to query the
currently supported voice protocol.
If the voice protocol needs to be switched, you need to delete the MG interface first and
run the protocol support command to switch the protocol. After the configuration is
complete, save the configuration and restart the system to make the configured protocol
take effect.
CAUTION
Plan.
Media
Media and
and
signaling upstream
signalin
VLAN
g
Media and
paramet
signaling upstream
ers
port
Media IP address
and signaling IP
address
Default gateway
IP address
SIP interface ID
Signaling port ID
IP address of the main IMS
equipment
Port ID of the main IMS
equipment
Coding scheme
Transmission mode
Home domain name (SIP)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11 FTTB and FTTC Solution Configuration
11.2.5 Principle of VoIP
Data
200
0/0/1
10.10.10.10/24
10.10.10.1/24
0
5060
200.200.200.200/24
5060
Text
UDP
huawei
873