Commissioning The Management Channel To The Xdsl Cpe - Huawei SmartAX MA5603T Configuration Manual

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
Result
After the commissioning is complete, you can maintain and manage the ONT on the MA5600T/
MA5603T/MA5608T (For example, run the ont deactivate command to deactivate the ONT
that is in the activated state).
Configuration File
vlan 20 smart
port vlan 20 0/19 0
interface vlanif 20
ip address 192.168.1.100 255.255.255.0
quit
dba-profile add profile-id 12 type1 fix 10240
ont-lineprofile gpon profile-id 5
tcont 1 dba-profile-id 12
gem add 0 eth tcont 1
gem mapping 0 0 vlan 20
commit
quit
interface gpon 0/2
ont add 0 0 sn-auth 32303131B39FD641 snmp ont-lineprofile-id 5
ont ipconfig 0 0 static ip-address 192.168.1.200 mask 255.255.255.0 vlan 20
quit
service-port vlan 20 gpon 0/2/0 ont 0 gemport 0 multi-service user-vlan 20
save

1.4.8 Commissioning the Management Channel to the xDSL CPE

This topic describes how to commission the CPE management function of the MA5600T/
MA5603T/MA5608T to ensure that you can log in to the CPE from the DSLAM at the CO to
remotely maintain and manage the CPE.
Service Requirements
In the network as shown in
l
l
l
Issue 01 (2014-04-30)
Figure
The maintenance terminal is connected to the maintenance Ethernet port of the MA5600T/
MA5603T/MA5608T.
After the management channel between the DSLAM and the CPE is set up, you can log in
to the CPE using port 0/2/0 connected to the CPE to remotely maintain and manage the
CPE.
The user access mode is IPoA.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1-83, the service requirements are as follows:
1 Commissioning